For more information, see the maintenance and service guide on the Hewlett Packard Enterprise website.
1610-Temperature violation detected
Symptom
1610-Temperature violation detected. Waiting 5 Minutes for System to Cool. Press Esc key to resume booting
without waiting for the system to cool. WARNING: Pressing Esc is NOT recommended as the system may
shutdown unexpectedly.
Cause
The temperature measured by one of the system temperature sensors has exceeded acceptable levels. In
many cases, this is due to the ambient inlet air temperature exceeding acceptable levels.
Action
Be sure to follow all the environmental, space, airflow, and temperature requirements for the .
For more information, see the user guide on the Hewlett Packard Enterprise website.
1611-CPU Zone Fan Assembly Failure Detected
Symptom
1611-CPU Zone Fan Assembly Failure Detected. Either the Assembly is not installed or multiple fans have
failed in the CPU zone.
Cause
Required fans are missing or not spinning.
Action
Make sure that all required fans are installed correctly and spinning. For more information, see "Fan issues" in
the HPE ProLiant Gen9 Troubleshooting Guide, Volume I on the Hewlett Packard Enterprise website.
1611-CPU Zone Fan Assembly Failure Detected
Symptom
1611-CPU Zone Fan Assembly Failure Detected. Single fan failure. Assembly will provide adequate cooling.
Cause
A redundant fan is missing or not spinning.
Action
Replace the fan to provide redundancy, if applicable. For more information, see the maintenance and service
guide on the Hewlett Packard Enterprise website.
1611-Fan failure detected
Symptom
1611-Fan failure detected.