The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24724
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that an error log update has occurred for the
physical drive with BMIC device index <device index>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message identifiers 24725-24749
Message Id: 24725
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that the consistency initialization pass has
completed for logical drive <logical drive number>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24726
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported an uncorrectable read error during surface
analysis operations for logical drive <logical drive number>. A media error was
encountered that is not correctable due to media errors on other physical
drive(s) belonging to this logical volume. The uncorrectable media defects are
between logical block address <lba number 1> and logical block address <lba
number 2>. The host will be unable to read some blocks between this address
range until the blocks are overwritten. Capacity expansion operations must be
avoided while the blocks are unreadable.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24727
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that the surface analysis uncorrectable read
error condition for logical drive <logical drive number> has ended. The
previously reported media defects have been overwritten. Capacity expansion
operations may now be conducted.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24728
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that a firmware update is needed for the
physical drive with product ID <ID number>. The recommended minimum firmware
revision should be <firmware revision number>.
206 Message identifiers 24725-24749