Log message: Snapshot resource volume of logical drive <logical drive number> on
<external specification> array controller <controller name / slot information>
has reached its limit.
<external specification> values:
the external controller attached to
""
Message Id: 24673
Severity: Informational
Log message: Power supply number <power supply number> was <inserted / removed>.
This power supply is located in the storage chassis with serial number <serial
number> which is attached to port <port number> of array controller <controller
name / slot information>.
Message Id: 24674
Severity: Warning
Log message: Array controller <controller name / slot information> is reporting
inconsistent data that was previously consistent.<additional data> The
inconsistent data may be caused by a power loss during write activity or by a
drive returning corrupt data. The inconsistent data is between block address
<block address 1> and block address <block address 2> of logical drive <logical
drive number>.
<additional data> values:
The parity data does not match the data drives.
“”
Message identifiers 24675-24699
Message Id: 24675
Severity: Warning
Log message: Data that was previously consistent is now being reported as
inconsistent.<additional data> The inconsistent data may be caused by a power
loss during write activity or by a drive returning corrupt data. The
inconsistent data is between block address <block address 1> and block address
<block address 2> of logical drive <logical drive number>. The inconsistent
physical drive can be found in bay <bay number> of box <box number> connected to
port <port number> of array controller <controller name / slot information>.
<additional data> values:
The parity data does not match the data drives.
“”
Message Id: 24676
Severity: Informational
Log message: Surface analysis has repaired an inconsistent stripe on logical drive
<logical drive number>. This repair was conducted by overwriting the