After pressing the F2 key, check the integrity of the file system and restore lost data from backup.
179A-Slot X Drive Array – Flash Backed Write Cache has been disabled
Symptom
179A-Slot X Drive Array - Flash Backed Write Cache has been disabled due to operation error. Action:
Replace Flash Backed Write Cache module.
Cause
The cache module has failed.
Action
Replace the cache module. For more information, see the maintenance and service guide on the Hewlett
Packard Enterprise website.
1800 Series
1802-Slot # Drive Array – Dual domain configured or detected
Symptom
1802-Slot # Drive Array – Dual domain configured or detected but is not supported due to a missing or
expired license key. Action: Enter HP Smart Array Advanced Pack License Key.
Cause
A license key is missing or has expired.
Action
Enter a new or valid HPE Smart Array Advanced Pack License Key.
1803-Slot X Drive Array – Cache Module is not installed
Symptom
1803-Slot X Drive Array – Cache Module is not installed. IMPORTANT: Unsupported Configuration: Controller
performance and supported configurations are limited. Action: Install the Cache Module to remove these
limitations.
Cause
The cache module is not installed.
179A-Slot X Drive Array – Flash Backed Write Cache has been