Message Id: 24645
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is not
redundant because it is using a different cache size than its partner
controller.
Message Id: 24646
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is not
redundant because its partner controller has reported a cache failure.
Message Id: 24647
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is no
longer redundant because this controller and its partner controller can no
longer see all the physical drives.
Message Id: 24648
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is no
longer redundant because one or more drives has been determined not to be able
to support redundant controller operations.
Message Id: 24649
Severity: Warning
Log message: The Smart Array controller <controller name / slot information> is no
longer redundant because an expand operation is in progress. The controller will
become redundant once again once the expand operation has completed.
Message identifiers 24650-24674
Message Id: 24650
Severity: Informational
Log message: SnapShot ID <ID number> of logical drive <logical drive number> on
<external specification> array controller <controller name / slot information>
has been created.
<external specification> values:
the external controller attached to
""
Message Id: 24651
Severity: Error
Log message: SnapShot ID <ID number> of logical drive <logical drive number> on
<external specification> array controller <controller name / slot information>
failed and has been deleted.
<external specification> values:
Message identifiers 24650-24674 189