Log message: Fan module <fan module number> is reporting that it is now
operational. This fan module is located in box number <box number> which is
connected to port <port number> of array controller <controller name / slot
information>.
Message Id: 24637
Severity: Informational
Log message: A previously failed storage enclosure processor (SEP) is now
responding and operational. This SEP is located in box <box number> which is
connected to port <port number> of array controller <controller name / slot
information>.
Message Id: 24638
Severity: Error
Log message: A storage enclosure processor (SEP) has failed. This SEP is located in
box <box number> which is connected to port <port number> of array controller
<controller name / slot information>.
Message Id: 24639
Severity: Error
Log message: All of the storage enclosure processors (SEPs) in box <box number>
have failed and there is currently no environmental management and monitoring
available for this storage box. Box <box number> is connected to port <port
number> of array controller <controller name / slot information>.
Message Id: 24640
Severity: Informational
Log message: The Smart Array controller <controller name / slot information> is now
redundant.
Message Id: 24641
Severity: Warning
Log message: The Smart Array controller <controller name / slot information> is
reporting that no redundant array controller is installed.
Message Id: 24642
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is not
redundant because it is a different model than its partner controller.
Message Id: 24643
Severity: Warning
Log message: The Smart Array controller <controller name / slot information> is not
redundant because an inter-controller link could not be established with the
partner controller.
Message Id: 24644
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is not
redundant because it is of a different firmware revision than its partner
controller.
188 HPE Smart Array errors