Supporting SNMP Trap Description: “Cache Accelerator errors may require a replacement module.”
Event Identifiers 1025-1092
NT Event ID: 1025 (Hex)0x84350401 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Advanced Memory Protection subsystem has detected a memory fault. The Online Spare
Memory has been activated. Schedule server down time to replace the memory.
SNMP Trap: cpqHeResilientMemOnlineSpareEngaged - 6047 in CPQHLTH.MIB
Symptom: Advanced Memory Protection Online Spare Engaged. The Advanced Memory Protection
subsystem has detected a memory fault. The Online Spare Memory has been activated.
User Action: Schedule server down time to replace the faulty memory.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “The Advanced Memory Protection subsystem has engaged the online
spare memory.”
NT Event ID: 1026 (Hex)0x84350402 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Advanced Memory Protection sub-system has detected a memory fault. The Mirrored
Memory has been activated. Schedule server down time to replace the memory.
SNMP Trap: cpqHeResilientMemMirroredMemoryEngaged - 6051 in CPQHLTH.MIB
Symptom: Advanced Memory Protection Mirrored Memory Engaged. The Advanced Memory Protection
subsystem has detected a memory fault. Mirrored Memory has been activated.
User Action: Replace the faulty memory.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “The Advanced Memory Protection subsystem has engaged the online
spare memory.”
NT Event ID: 1027 (Hex)0x84350403 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Advanced Memory Protection sub-system has detected a memory fault. Advanced ECC
has been activated. Schedule server down time to replace the memory.
SNMP Trap: cpqHeResilientAdvancedECCMemoryEngaged - 6052 in CPQHLTH.MIB
Symptom: Advanced Memory Protection Advanced ECC Memory Engaged. The Advanced Memory
Protection subsystem has detected a memory fault. Advanced ECC has been activated.
User Action: Replace the faulty memory.
Supporting SNMP Trap Data: