Cause
The power supply is not seated correctly.
The power cable is not connected correctly.
The power supply has failed.
Action
1. Reseat the power supply.
2. Make sure that the power cable is connected correctly.
3. If the issue persists, replace the power supply.
For more information, see the maintenance and service guide for your product on the Hewlett Packard
Enterprise website.
Storage Enclosure: Warning: The enclosure is reporting a high temperature status
Symptom
Storage Enclosure: Warning: The enclosure is reporting a high temperature status.
Cause
A required fan is missing or not spinning.
One or more fans have failed.
Airflow from the fans is obstructed.
Action
1. Be sure that all fans are connected and operating.
2. Replace any defective fans.
For more information, see the maintenance and service guide for your product on the Hewlett Packard
Enterprise website.
3. For better airflow, remove any dust buildup from fans or other areas.
4. If the issue persists, contact Hewlett Packard Enterprise support. For more information, see "Accessing
Hewlett Packard Enterprise support."
POST error messages
Introduction to POST error messages
The error messages and codes in this section include all messages generated by ProLiant servers. Some
messages are informational only and do not indicate any error. A server generates only those codes that are