EasyManua.ls Logo

HPE ProLiant Gen9

HPE ProLiant Gen9
460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqFcTapeLibraryCntlrIndex
cpqFcTapeLibraryScsiBus
cpqFcTapeLibraryScsiTarget
cpqFcTapeLibraryScsiLun
cpqFcTapeLibraryModel
cpqFcTapeLibraryFWRev
cpqFcTapeLibrarySerialNumber
cpqFcTapeLibraryLocation
cpqFcTapeLibraryDoorStatus
Supporting SNMP Trap Description: “The door is [cpqFcTapeLibraryDoorStatus] for tape library.”
NT Event ID: 1199 (Hex)0x843504af (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Controller Status Change.
Log Message: The Drive Array Controller in %7 has a new status of %5.
SNMP Trap: cpqDa6CntlrStatusChange - 3033 in CPQIDA.MIB
Symptom: Controller Status Change. This trap indicates that the agent has detected a change in the status of
a drive array controller. The variable cpqDaCntlrBoardStatus indicates the current controller status.
User Action: If the board status is generalFailure(3), you may need to replace the controller. If the board
status is cableProblem(4), check the cable connections between the controller and the storage system.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaCntlrIndex
cpqDaCntlrBoardStatus
cpqDaCntlrModel
cpqDaCntlrSerialNumber
cpqDaCntlrFWRev
cpqDaAccelTotalMemory
Supporting SNMP Trap Description: “Status is now [cpqDaCntlrBoardStatus].”
Event Identifiers 1200-1294
NT Event ID: 1200 (Hex)0x843504b0 (cpqstmsg.dll)
374 Event Identifiers 1200-1294

Table of Contents

Other manuals for HPE ProLiant Gen9

Related product manuals