Log Severity: Warning (2)
Event Title: Drive Array Logical Drive Status Change.
Log Message: Logical drive number %5 on the array controller in %4 has a new status of %2.
SNMP Trap: cpqDa6LogDrvStatusChange - 3034 in CPQIDA.MIB
Symptom: Logical Drive Status Change. This trap indicates that the agent has detected a change in the status
of a drive array logical drive. The variable cpqDaLogDrvStatus indicates the current logical drive status.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaLogDrvCntlrIndex
cpqDaLogDrvIndex
cpqDaLogDrvStatus
Supporting SNMP Trap Description: “Status is now [cpqDaLogDrvStatus].”
NT Event ID: 1201 (Hex)0x843504b1 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Spare Drive Status Change.
Log Message: The spare drive in %4, port %5, bay %6 has a new status of %2.
SNMP Trap: cpqDa6SpareStatusChange - 3035 in CPQIDA.MIB
Symptom: Spare Drive Status Change. This trap indicates that the agent has detected a change in the status
of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare drive status.
User Action: If the spare drive status is failed, replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaSpareCntlrIndex
cpqDaSparePhyDrvIndex
cpqDaSpareStatus
cpqDaSpareBusNumber
cpqDaSpareBay
Supporting SNMP Trap Description: “Spare Status is now [cpqDaSpareStatus].”
NT Event ID: 1202 (Hex)0x843504b2 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Physical Drive Status Change.
Log Message: The physical drive in %4, port %5, bay %6 with serial number “%7”, has a new status of %2.
HPE Insight Management Agents for Servers for Windows 375