SNMP Trap: cpqDa6PhyDrvStatusChange - 3036 in CPQIDA.MIB
Symptom: Physical Drive Status Change. This trap indicates that the agent has detected a change in the
status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive
status.
User Action: If the physical drive status is failed(3) or predictive Failure(4), replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaPhyDrvIndex
cpqDaPhyDrvBusNumber
cpqDaPhyDrvBay
cpqDaPhyDrvModel
cpqDaPhyDrvFWRev
cpqDaPhyDrvSerialNum
cpqDaPhyDrvFailureCode
cpqDaPhyDrvStatus
Supporting SNMP Trap Description: “Physical Drive Status is now [cpqDaPhyDrvStatus].”
NT Event ID: 1203 (Hex)0x843504b3 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Physical Drive Threshold Exceeded.
Log Message: The physical drive in %4, port %5, bay %6 with serial number “%7”, has exceeded a drive
threshold.
SNMP Trap: cpqDa6PhyDrvThreshPassedTrap - 3037 in CPQIDA.MIB
Symptom: Physical Drive Threshold Passed. This trap indicates that the agent has detected a factory
threshold associated with one of the physical drive objects on a drive array has been exceeded.
User Action: Replace the physical drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaPhyDrvCntlrIndex
cpqDaPhyDrvIndex
cpqDaPhyDrvBusNumber
cpqDaPhyDrvBay
cpqDaPhyDrvModel
376 HPE Insight Management Agents for Servers for Windows