Event identifier: cpqhsmsg.dll - 1808 (Hex)0x44350710 (Service Event)
Log Severity: Information (1)
Log Message: The agent could not deliver trap %1. The agent was unable to use Asynchronous Management
to deliver a trap. This can be caused by a failure in the Remote Access Service or by a missing or invalid
configuration. Use the Management Agents control panel to verify the Asynchronous Management
configuration settings. Use the Network control panel to verify the Remote Access configuration. If this error
persists, reinstalling the Management Agents or the Remote Access Service may correct this error. For more
information, see the Management Agents Asynchronous Management documentation.
Event Identifiers 2048-2359
Event identifier: cpqhsmsg.dll - 2048 (Hex)0x84350800 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to allocate memory. This indicates a low memory condition. Rebooting the system will
correct this error.
Event identifier: cpqhsmsg.dll - 2049 (Hex)0x84350801 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to read from the registry. This error can be caused by a corrupt registry or a low
memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 2050 (Hex)0x84350802 (Service Event)
Log Severity: Warning (2)
Log Message: Could not create the registry sub-key: “%1”. This error can be caused by a corrupt registry or a
low memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 2051 (Hex)0x84350803 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to read from the registry. This error can be caused by a corrupt registry or a low
memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 2052 (Hex)0x84350804 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to read “%1” from the registry. This error can be caused by a corrupt registry or a low
memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 2053 (Hex)0x84350805 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to read “%1” from the registry. This error can be caused by a corrupt registry or a low
memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 2056 (Hex)0x84350808 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to create thread. This error can be caused by a low memory condition. Rebooting the
server may correct this error.
Event identifier: cpqhsmsg.dll - 2098 (Hex)0x84350832 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to acquire file system information. This error can be caused by an unformatted partition
or by a partition that has been recently modified. Formatting the partition or rebooting the server may correct