Description: A profile has iSCSI boot enabled on an unsupported Flex-10 NIC.
Possible cause: An administrator has incorrectly configured the boot settings for the profile.
Actions:
Correct the specified profile settings to enable the iSCSI boot on a supported NIC.
Remove the iSCSI configuration from profile.
Insert a supported NIC card to configure iSCSI boot.
6023 - Profile is assigned to a multi-blade server that has data missing
Severity: MAJOR
Description: VCM does not have information about all of the bays in multi-blade server. The GUI should
show the appropriate state.
Possible cause: All the blades of the server could not complete initialization successfully; therefore, some
blades in the multi-blade server are not yet discovered.
Actions:
Check the status of the bays for an indication of the problem.
Remove and install the server into the bays that are indicating an error.
Reboot the server and check to see if it is discovered.
Physically remove and replace the server.
Analyze the Onboard Administrator logs for possible details regarding the failure.
6030 - Profile could not be assigned to powered up server
Severity: MAJOR
Description: A profile was changed or assigned and some configuration required that the server be powered
off to make the change. For example, if the number of Ethernet connections is changed for a profile that is
assigned to a server with Flex-10 NICs, then the server must be powered off.
Possible causes:
A user action results in a profile that requires the server be powered off to make the change or initially
assign or remove the profile.
VCM restarts and detects a powered on server that has a profile assigned to the bay and the profile needs
to make a change on the server that requires it to be powered off.
Action: Power down the server and retry the change.
Ethernet Network events (7000-7999)
7012 - Enet Network state FAILED
Severity: CRITICAL
Description: The VC Enet Network lost all uplink connectivity because of lack of configured ports or all
configured ports are in a bad state or because a bad or incompatible transceiver was inserted.
Possible causes:
296 6023 - Profile is assigned to a multi-blade server that has data missing