EasyManua.ls Logo

HPE ProLiant Gen9 - Event Identifiers 1343-4613

HPE ProLiant Gen9
460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Event identifier: cpqstmsg.dll - 1283 (Hex)0x84350503 (Service Event)
Log Severity: Warning (2)
Log Message: Could not read the registry subkey: “%1”. This error can be caused by a corrupt registry or a
low memory condition. Rebooting the server may correct this error.
Event identifier: cpqstmsg.dll - 1284 (Hex)0x84350504 (Service Event)
Log Severity: Warning (2)
Log Message: Could not write the registry subkey: “%1”. This error can be caused by a corrupt registry or a
low memory condition. Rebooting the server may correct this error.
Event identifier: cpqstmsg.dll - 1285 (Hex)0x84350505 (Service Event)
Log Severity: Warning (2)
Log Message: Could not write the registry subkey: “%1”. This error can be caused by a corrupt registry or a
low memory condition. Rebooting the server may correct this error.
Event identifier: cpqstmsg.dll - 1294 (Hex)0x8435050e (Service Event)
Log Severity: Warning (2)
Log Message: Unsupported storage system. The ProLiant storage system %1 is unsupported by this version
of the Storage Agents. Upgrade the agents to the latest version.
Event Identifiers 1343-4613
Event identifier: cpqstmsg.dll - 1343 (Hex) 0x8435053f (Service Event)
Log Severity: Warning (2)
Log Message: Duplicate SCSI port found in slot %1. The current system ROM may not support this SCSI
controller. You may need to update your system ROM.
Event identifier: cpqstmsg.dll - 1344 (Hex) 0x84350540 (Service Event)
Log Severity: Warning (2)
Log Message: A version mismatch has been detected with the SCSI device monitor driver (CPQSDM.SYS).
The current driver version is %1.
Cause: You may not have rebooted after a Storage Agents upgrade. Always reboot the system after installing
agents.
Event identifier: cpqstmsg.dll – 1346 (Hex) 0x84350540 (Service Event)
Log Severity: Warning (2)
Log Message: The SCSI controller on port %1 has been omitted. The SCSI Agent could not get the slot data
for the controller.
Event identifier: cpqstmsg.dll - 1792 (Hex) 0x84350700 (Service Event)
Log Severity: Warning (2)
Log Message: The SNMP Agent is unable to generate traps due to an error during initialization.
Cause: The SNMP service might not be running. Reinstalling the agents may fix this error.
Event identifier: cpqstmsg.dll - 1795 (Hex) 0x84350703 (Service Event)
Log Severity: Warning (2)
Log Message: The SNMP Agent is older than other components. The SNMP Agent is older than the other
components of the Storage Agents. Reinstall the entire Storage Agents package to correct this error.
Event identifier: cpqstmsg.dll - 1796 (Hex) 0x84350704 (Service Event)
392 Event Identifiers 1343-4613