• cpqDaPhyDrvSerialNum
• cpqDaPhyDrvSSDWearStatus
• cpqSasPhyDrvSSDWearStatus
Supporting SNMP Trap Description: "Solid State Disk Wear Status is now %d."
NT Event ID: 1228 (Hex)0x843504cc (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: IDE Disk SSD Wear Status Change.
Log Message: The ATA disk drive with model %6 and serial number %7 has a new solid state wear status of
%2. (SSD wear status values: 1=other, 2=ok, 3=fiftySixDayThreshold, 4=fivePercentThreshold,
5=twoPercentThreshold, 6=ssdWearOut)
SNMP Trap: cpqIdeAtaDiskSSDWearStatusChange - 14006 in CPQIDE.MIB
Symptom: This trap signifies that the agent has detected a change in the SSD wear status of a SATA physical
drive. The variable cpqIdeAtaDiskSSDWearStatus indicates the current SSD wear status.
User Action: If the SSD wear status is ssdWearOut(6), replace the drive.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqIdeAtaDiskControllerIndex
• cpqIdeAtaDiskIndex
• cpqIdeAtaDiskModel
• cpqIdeAtaDiskFwRev
• cpqIdeAtaDiskSerialNumber
• cpqIdeAtaDiskSSDWearStatus
• cpqIdeAtaDiskChannel
• cpqIdeAtaDiskNumber
Supporting SNMP Trap Description: "Solid State Disk Wear Status is now %d."
Event identifier: cpqstmsg.dll - 1280 (Hex)0x84350500 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to allocate memory. This indicates a low memory condition. Rebooting the system will
correct this error.
Event identifier: cpqstmsg.dll - 1281 (Hex)0x84350501 (Service Event)
Log Severity: Warning (2)
Log Message: Could not read from the registry subkey. This error can be caused by a corrupt registry or a low
memory condition. Rebooting the server may correct this error.
Event identifier: cpqstmsg.dll - 1282 (Hex)0x84350502 (Service Event)
Log Severity: Warning (2)
Log Message: Could not write the registry subkey: “%1”. This error can be caused by a corrupt registry or a
low memory condition. Rebooting the server may correct this error.
HPE Insight Management Agents for Servers for Windows 391