Symptom: The agent has detected a change in the SSD wear status of a SAS or SATA physical drive. The
variable cpqSasPhyDrvSSDWearStatus indicates the current SSD wear status.
User Action: If the SSD wear status is ssdWearOut(6), replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSasHbaHwLocation
cpqSasPhyDrvLocationString
cpqSasPhyDrvHbaIndex
cpqSasPhyDrvIndex
cpqSasPhyDrvType
cpqSasPhyDrvModel
cpqSasPhyDrvFWRev
cpqSasPhyDrvSerialNumber
cpqSasPhyDrvSasAddress
Supporting SNMP Trap Description: "Solid State Disk Wear Status is now %d."
NT Event ID: 1227 (Hex)0x843504cb (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Physical Drive SSD Wear Status Change.
Log Message: The physical drive in %4, %5 with serial number "%6", has a new solid state wear status of
%7. (Drive status values: 1=other, 2=ok, 3=fiftySixDayThreshold, 4=fivePercentThreshold,
5=twoPercentThreshold, 6=ssdWearOut)
SNMP Trap: cpqDaPhyDrvSSDWearStatusChange- 3049 in CPQIDA.MIB
Symptom: This trap signifies that the agent has detected a change in the SSD wear status of a drive array
physical drive. The variable cpqDaPhyDrvSSDWearStatus indicates the current SSD wear status.
User Action: If the SSD wear status is ssdWearOut(6), replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqDaCntlrHwLocation
cpqDaPhyDrvCntlrIndex
cpqDaPhyDrvIndex
cpqDaPhyDrvLocationString
cpqDaPhyDrvType
cpqDaPhyDrvModel
cpqDaPhyDrvFWRev
390 HPE Insight Management Agents for Servers for Windows