Action
Replace the cache module. For more information, see the maintenance and service guide on the Hewlett
Packard Enterprise website.
1799-Slot X Drive Array – Drive(s) Disabled due to Cache Data Loss
Symptom
1799-Slot # Drive Array - Drive(s) Disabled due to Cache Data Loss.
Select “F1” to continue with logical drives disabled.
Select “F2” to accept data loss and to re-enable logical drives.
Cause
One or more logical drives failed due to loss of data in posted-writes memory.
Action
1. Do one of the following:
Press the F1 key to continue with the logical drives disabled.
Press the F2 key to accept data loss and re-enable logical drives.
After pressing the F2 key, check the integrity of the file system and restore lost data from backup.
1799-Slot X Drive Array – Drive(s) Disabled due to Write-Back Cache Data Loss
Symptom
1799-Slot X Drive Array – Drive(s) Disabled due to Write-Back Cache Data Loss.
Select “F1” to continue with logical drives disabled.
Select “F2” to accept data loss and to re-enable logical drives.
Cause
One or more logical drives failed due to loss of data in posted-writes memory.
Action
1. Do one of the following:
Press the F1 key to continue with the logical drives disabled.
Press the F2 key to accept data loss and re-enable logical drives.
152 1799-Slot X Drive Array – Drive(s) Disabled due to Cache Data Loss