Message ID: 24718
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that logical drive <logical drive number>
returned a fatal error during a read/write request from/to the volume.
Logical block address <lba number>, block count <block count> and command
<command number> were taken from the failed logical I/O request.
The external Smart Array controller is also reporting that the last physical
drive to report a fatal error condition(associated with this specific logical
request), is located on bus <bus number> and ID <ID number>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24719
Severity: Warning
Log message: The event information received from the external Smart Array
controller located in the MSA chassis labeled as <chassis label> was of an
unknown or unrecognized class.
An excerpt of the controller message is as follows: <firmware message>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24720
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that its cache has been disabled.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24721
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that its cache has been enabled.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24722
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that its cache batteries are missing.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24723
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that its cache batteries have failed.
HPE Smart Array errors 205