Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that logical drive <logical drive number> is in
a failed state but has had one or more drive replacements and is now ready to
change to a status of "OK". However, this status change will not occur until the
logical drive is re-enabled. Please re-enable the logical drive either via the
Array Configuration Utility or by power cycling the MSA chassis.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24714
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that the recovery of logical drive <logical
drive number> was aborted while rebuilding due to an unrecoverable read error.
Physical drive number <physical drive number 1> was the replacement drive being
rebuilt before the read error occurred, while physical drive number <physical
drive number 2> is the error drive which reported the read error.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24715
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that due to an unrecoverable read error, the
recovery of logical drive <logical drive number> was aborted while rebuilding a
physical drive. The physical drive which was being rebuilt is located in bay
<bay number 1> of the MSA chassis. The physical drive that reported the read
error is located in bay <bay number 2> of the MSA chassis.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24716
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that the recovery of logical drive <logical
drive number> was aborted while rebuilding due to an unrecoverable write error.
Physical drive number <physical drive number 1> was the replacement drive being
rebuilt before the write error occurred, while physical drive number <physical
drive number 2> is the error drive which reported the write error.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message ID: 24717
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that due to an unrecoverable write error, the
recovery of logical drive <logical drive number> was aborted while rebuilding a
physical drive. The physical drive which was being rebuilt is located in bay
<bay number 1> of the MSA chassis. The physical drive that reported the write
error is located in bay <bay number 2> of the MSA chassis.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
204 HPE Smart Array errors