Cause
The real-time clock system battery is running low on power.
Action
Replace the system battery. For more information, see the maintenance and service guide on the Hewlett
Packard Enterprise website.
1614-Redundant Fan Failure
Symptom
1614-Redundant Fan Failure.
Cause
A redundant fan is missing or not spinning.
Action
Make sure that all required fans are installed correctly and spinning. For more information, see "Fan issues" in
the HPE ProLiant Gen9 Troubleshooting Guide, Volume I on the Hewlett Packard Enterprise website.
1616-Power Supply Configuration Failure
Symptom
1616-Power Supply Configuration Failure
– A working power supply must be installed in Bay 1 for proper cooling.
– System Halted!
Solution 1
Cause
The power supply is missing.
Action
Install the power supply.
For more information, see the maintenance and service guide on the Hewlett Packard Enterprise website
Solution 2
Cause
The power supply has failed.
Action
Replace the power supply.
110 1614-Redundant Fan Failure