Action
No action is required.
1795-Slot X Drive Array – Cache Module Configuration Error
Symptom
1795-Slot X Drive Array – Cache Module Configuration Error. Data does not correspond to this drive array.
Caching is temporarily disabled.
Cause
• Power was interrupted while data was in the cache.
• The controller was ungracefully shut down, moved to another server, and then attached to a new volume.
Action
1. To discard this data, select the F9 key to access System Utilities while the system ROM is booting.
2. From the System Utilities menu, select System Health View > System Health.
3. Select the HPE Smart Array controller.
4. Select Health Status: Configuration Required.
5. Under Select logical drives operation, choose Repair. Erase data held in Write-Back Cache.
1796-Slot X Drive Array – Flash Backed Write Cache module is not
Symptom
1796-Slot X Drive Array - Flash Backed Write Cache module is not responding. Action: Turn off power and
reseat the Flash Backed Write Cache Module. If error persists, replace module.
Cause
• The cache module is missing.
• The cache module has failed.
Depending on the array controller model, the cache might be disabled or the controller might not be usable
until the issue is corrected.
Action
1. Reseat the cache module.
2. If the issue persists, replace the cache module.
For more information, see the maintenance and service guide on the Hewlett Packard Enterprise
website.