• “READY FOR RECOVERY”
• “RECOVERING”
• “WRONG PHYSICAL DRIVE REPLACED”
• “PHYSICAL DRIVE NOT PROPERLY CONNECTED”
• “HARDWARE IS OVERHEATING”
• “HARDWARE HAS OVERHEATED”
• “EXPANDING”
• “NOT YET AVAILABLE”
• “QUEUED FOR EXPANSION”
• “DISABLED DUE TO SCSI ID CONFLICT”
• “EJECTED”
• “ERASING”
• “UNKNOWN”
Message ID: 24601
Severity: Informational
Log message: Logical drive <logical drive number> configured on array controller
<controller name / slot information> is in a failed state but has had one or
more drive replacements and is now ready to change to a status of "OK". However,
this status change will not occur until the logical drive is re-enabled. Please
re-enable the logical drive either via the Array Configuration Utility or by
rebooting the system.
Message ID: 24602
Severity: Warning
Log message: The recovery of logical drive <logical driver number> configured on
array controller <controller name / slot information> was aborted while
rebuilding due to an unrecoverable read error. Physical drive number <physical
drive number> was the replacement drive being rebuilt before the read error
occurred, while physical drive number <physical drive number> is the error drive
which reported the read error.
Message ID: 24603
Severity: Warning
Log message: Due to an unrecoverable read error, the recovery of logical drive %3
configured on array controller <controller name / slot information> was aborted
while rebuilding a physical drive.
The physical drive which was being rebuilt is located in bay <bay number> of box
<box number> which is connected to port <port number> of array controller
<controller name / slot information>.
The physical drive that reported the read error is located in bay <bay number>
of box <box number> which is connected to port <port number> of array controller
<controller name / slot information>.
Message ID: 24604
182 HPE Smart Array errors