Loading...
READY FOR RECOVERY
RECOVERING
WRONG PHYSICAL DRIVE REPLACED
PHYSICAL DRIVE NOT PROPERLY CONNECTED
HARDWARE IS OVERHEATING
HARDWARE HAS OVERHEATED
EXPANDING
NOT YET AVAILABLE
QUEUED FOR EXPANSION
DISABLED DUE TO SCSI ID CONFLICT
EJECTED
ERASING
UNKNOWN
Message ID: 24601
Severity: Informational
Log message: Logical drive <logical drive number> configured on array controller
<controller name / slot information> is in a failed state but has had one or
more drive replacements and is now ready to change to a status of "OK". However,
this status change will not occur until the logical drive is re-enabled. Please
re-enable the logical drive either via the Array Configuration Utility or by
rebooting the system.
Message ID: 24602
Severity: Warning
Log message: The recovery of logical drive <logical driver number> configured on
array controller <controller name / slot information> was aborted while
rebuilding due to an unrecoverable read error. Physical drive number <physical
drive number> was the replacement drive being rebuilt before the read error
occurred, while physical drive number <physical drive number> is the error drive
which reported the read error.
Message ID: 24603
Severity: Warning
Log message: Due to an unrecoverable read error, the recovery of logical drive %3
configured on array controller <controller name / slot information> was aborted
while rebuilding a physical drive.
The physical drive which was being rebuilt is located in bay <bay number> of box
<box number> which is connected to port <port number> of array controller
<controller name / slot information>.
The physical drive that reported the read error is located in bay <bay number>
of box <box number> which is connected to port <port number> of array controller
<controller name / slot information>.
Message ID: 24604
182 HPE Smart Array errors