The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
<firmware error code> values:
TOO_SMALL_IN_LOAD_CONFIG - Replacement drive is too small for configured
volume(s).
ERROR_ERASING_RIS - Could not write to reserved configuration sectors after
multiple retries.
ERROR_SAVING_RIS - Could not write to reserved configuration sectors after
multiple retries.
FAIL_DRIVE_COMMAND - “Fail Drive” command received from host.
MARK_BAD_FAILED - Unable to create media defect after multiple retries.
MARK_BAD_FAILED_IN_FINISH_REMAP - Unable to create media defect after multiple
retries.
TIMEOUT - Too many SCSI command timeouts.
AUTOSENSE_FAILED - Drive is failing commands but is not returning SCSI sense
data after multiple retries.
MEDIUM_ERROR_1 - Caused by a particular set of SCSI sense codes that indicate
the drive is in bad shape and its data may be corrupt.
MEDIUM_ERROR_2 - Caused by a particular set of SCSI sense codes that indicate
the drive is in bad shape; retries did not help.
NOT_READY_BAD_SENSE - Drive is returning unrecognized Not Ready sense codes.
NOT_READY - Drive is not ready and will not spin up.
HARDWARE_ERROR - Drive is returning a Hardware Error sense key; controller
unable to get drive back online.
ABORTED_COMMAND - Drive is returning an Aborted Command sense key; controller
unable to get drive back online.
WRITE_PROTECTED - Drive is returning a sense key indicating it is write
protected.
SPIN_UP_FAILURE_IN_RECOVER - “Start Unit” command failed during error recovery
REBUILD_WRITE_ERROR - Drive failed write command after multiple retries during
rebuild.
TOO_SMALL_IN_HOT_PLUG - Replacement drive is too small for configured
volume(s).
BUS_RESET_RECOVERY_ABORTED - Unable to communicate with drive after multiple
bus resets and retries; may be due to this drive or another drive that is
corrupting the parallel SCSI bus.
REMOVED_IN_HOT_PLUG - Drive has been hot-removed.
INIT_REQUEST_SENSE_FAILED - “Request Sense” command failed during device
discovery/initialization.