• WRITE_RETRIES_FAILED - Unable to complete a write operation after several
retries.
• QUEUE_FULL_ON_ZERO - Drive indicates that its queue is full when we have no
requests outstanding to the drive.
• SMART_ERROR_REPORTED - Drive has reported a predictive-failure error when
controller is configured to automatically fail [instead of reporting imminent
failure of] drives that report this error.
• PHY_RESET_FAILED - Phy reset request failed.
• FR_CHKBLK_FAILED_WRITE - Drive failed write command while checking for media
errors.
• FR_ATI_TEST_FAILED_WRITE - Drive failed write command while checking for
errors.
• OFFLINE_ERASE - Drive is offline due to a Secure Erase operation.
• OFFLINE_TOO_SMALL - Drive is offline because it’s a replacement drive that is
too small.
• OFFLINE_DRIVE_TYPE_MIX - Drive is offline because it is not the correct type
for this array [SATA vs SAS].
• OFFLINE_ERASE_COMPLETE - Drive is offline because a Secure Erase operation has
completed on it but it hasn’t been replaced yet.
Message ID: 24710
Severity: Informational
Log message:
The external Smart Array controller located in the MSA chassis labeled as
<chassis label> has reported that logical drive <logical drive number> has
encountered a status change from:
Status: <previous status>
to
Status: <current status>
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
<previous status> and <current status> values:
• “OK”
• “FAILED”
• “NOT CONFIGURED”
• “INTERIM RECOVERY MODE”
• “READY FOR RECOVERY”
• “RECOVERING”
• “WRONG PHYSICAL DRIVE REPLACED”
• “PHYSICAL DRIVE NOT PROPERLY CONNECTED”
HPE Smart Array errors 201