Severity: Error
Log message: The external Smart Array controllers located in the MSA chassis
labeled as <chassis label> are not redundant because they are different models.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24736
Severity: Error
Log message: The external Smart Array controllers located in the MSA chassis
labeled as <chassis label> are not redundant because an inter-controller link
could not be established.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24737
Severity: Error
Log message: The external Smart Array controllers located in the MSA chassis
labeled as <chassis label> are not redundant because the array controllers are
reporting different firmware revisions.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24738
Severity: Error
Log message: The external Smart Array controllers located in the MSA chassis
labeled as <chassis label> are not redundant because the array controllers are
reporting different cache sizes.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24739
Severity: Error
Log message: An external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting that it is not redundant because the other
external controller is reporting a cache failure.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24740
Severity: Error
Log message: The external Smart Array controllers located in the MSA chassis
labeled as <chassis label> are no longer redundant because both array
controllers cannot see all the physical drives.
The external Smart Array controller reporting this event is attached to the host
side Smart Array controller <controller name / slot information>.
Message Id: 24741
Severity: Error
208 HPE Smart Array errors