Logical drive migrate and extend operations are not possible while the erase operation is in progress.
Logical drive state: The logical drive is queued for expansion
Symptom
Logical drive state: The logical drive is queued for expansion.
Cause
A logical drive is queued for expansion.
Action
No action is required.
Logical drive state: The logical drive is queued for rebuilding
Symptom
Logical drive state: The logical drive is queued for rebuilding.
Cause
A logical drive is queued for rebuilding.
Action
No action is required.
Normal operations can occur; however, performance will be less than optimal during the rebuilding process.
Logical drive state: This logical drive has a high physical drive count
Symptom
Logical drive state: This logical drive has a high physical drive count as well as a high stripe size value such
that a controller lock up could occur. It is recommended that the stripe size be migrated to a lower value.
Cause
A logical drive has a high physical drive count and a high stripe size value that can lead to a controller lockup.
Action
Migrate the stripe size to a lower value using the HPE SSA.
For more information, see the HPE Smart Storage Administrator User Guide on the Hewlett Packard
Enterprise website.
NVRAM Error: Board ID could not be read
Symptom
NVRAM Error: Board ID could not be read (Read-Only Table failed checksum test). Unrecoverable error.