Trap Category Severity MIB
Output utilization above high-water
mark
2
VC-Enet Port
Threshold
WARNING VCM-MIB
Output utilization below low-water
mark
2
VC-Enet Port
Threshold
NORMAL VCM-MIB
Input errors above high-water mark
2
VC-Enet Port
Threshold
WARNING VCM-MIB
Input errors below low-water mark
2
VC-Enet Port
Threshold
NORMAL VCM-MIB
Output errors above high-water
mark
2
VC-Enet Port
Threshold
WARNING VCM-MIB
Output errors below low-water mark
2
VC-Enet Port
Threshold
NORMAL VCM-MIB
vcModPortBpduLoopDetected VC-Enet Port
Status
CRITICAL VCM-MIB
vcModPortBpduLoopCleared VC-Enet Port
Status
INFO VCM-MIB
vcModPortProtectionConditionDetect
ed
VC-Enet Port
Status
CRITICAL VCM-MIB
vcModPortProtectionConditionCleare
d
VC-Enet Port
Status
INFO VCM-MIB
1
Only supported by HPE VC 8Gb or 16Gb 24-Port FC modules
2
The VC Module MIB has the capability to send traps when certain bandwidth and throughput utilization
thresholds are reached. The counters are sampled at a fixed interval of 30 seconds and neither sample
interval nor threshold values are configurable in this release. Thresholds are defined as follows:
• Port utilization high water mark 95%
• Port utilization low water mark 75%
• Errors high water mark 5%
• Errors low water mark 1%
For more information, see the description field in the associated MIB.
3
For more information, see "VC Domain Managed Status Changed traps."
IMPORTANT:
During OA failover or other management network disruptions, VC SNMP traps might not reach the
management station.
The VC-FC module generates connUnitPortStatusChange traps based on changes to the connUnitPortStatus
element of the FA-MIB. The following table shows the mapping of connUnitPortStatusChange trap severities
to the VC Domain MIB's trap severity definitions.
HPE Virtual Connect errors 275