Action
No action is required.
Redundancy State: This controller has been setup to be part of a redundant pair of
controllers
Symptom
Redundancy State: This controller has been setup to be part of a redundant pair of controllers but redundancy
is disabled. Redundancy is disabled for an unknown reason.
Cause
Redundancy is disabled for an unknown reason.
Action
Contact Hewlett Packard Enterprise support. For more information, see "Accessing Hewlett Packard
Enterprise support."
Redundant Path Failure: Multi-domain path failure
Symptom
Redundant Path Failure: Multi-domain path failure.
Cause
A cable is not installed correctly.
A cable is damaged or has failed.
The storage box I/O module is not installed correctly.
The storage box I/O module has failed.
Action
Check the storage device I/O module and cables to restore redundant paths.
Redundant Path Failure: The logical drive is degraded due to the loss of a redundant path
Symptom
Redundant Path Failure: The logical drive is degraded due to the loss of a redundant path.
Cause
A cable is not installed correctly.
A cable is damaged or has failed.
The storage box I/O module is not installed correctly.
The storage box I/O module has failed.
30 Redundancy State: This controller has been setup to be part of a