SNMP Trap: cpqOsCacheCopyReadHitsDegraded - 19003 in CPQWINOS.MIB
Symptom: The Cache CopyReadHits performance property is set to degraded.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqOsCacheIndex
cpqOsCacheInstance
cpqOsCacheCopyReadHitsPercent
Supporting SNMP Trap Description: “The Cache performance property is degraded with Copy Read Hits of
[cpqOsCacheCopyReadHitsPercent] percent.”
NT Event ID: 1176 (Hex)0xc4350498 (cpqhsmsg.dll)
Log Severity: Error (3)
Log Message: The Cache Performance Instance, '%4' is failed with Cache Copy Read Hits of %5 percent.
SNMP Trap: cpqOsCacheCopyReadHitsFailed - 19004 in CPQWINOS.MIB
Symptom: The Cache Copy Read Hits performance property is set to critical.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqOsCacheIndex
cpqOsCacheInstance
cpqOsCacheCopyReadHitsPercent
Supporting SNMP Trap Description: “The Cache performance property is critical with Copy Read Hits of
[cpqOsCacheCopyReadHitsPercent] percent.”
NT Event ID: 1177 (Hex)0x84350499 (cpqhsmsg.dll)
Log Severity: Warning (2)
Log Message: The PagingFile Performance Instance, '%4' is degraded with PagingFile Usage of %5 percent.
SNMP Trap: cpqOsPageFileUsageDegraded - 19005 in CPQWINOS.MIB
Symptom: The PagingFile Usage performance property is set to degraded.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqOsPagingFileIndex
cpqOsPagingFileInstance
cpqOsPageFileUsagePercent
326 HPE Insight Management Agents for Servers for Windows