Action: Complete the following steps:
1. Be sure that the SNMP service is configured to allow SNMP requests from “localhost.”
2. Be sure that there is an adequate amount of free memory.
Event identifier: cpqhsmsg.dll - 4405 (Hex)0x84351135 (Service Event)
Log Severity: Warning (2)
Log Message: The External Status MIB Agent could not set the variable because it is unsupported. The data
contains the error code.
Event identifier: cpqhsmsg.dll - 4406 (Hex)0x84351136 (Service Event)
Log Severity: Warning (2)
Log Message: The External Status MIB Agent could not set the variable because the value is invalid or out of
range. The data contains the error code.
Event identifier: cpqhsmsg.dll - 4407 (Hex)0x84351137 (Service Event)
Log Severity: Warning (2)
Log Message: The External Status MIB Agent is not loaded. Sets are not available. The data contains the
error code.
Event identifier: cpqhsmsg.dll - 4608 (Hex)0x84351200 (Service Event)
Log Severity: Warning (2)
Log Message: Unable to allocate memory. This indicates a low memory condition. Rebooting the system will
correct this error.
Event identifier: cpqhsmsg.dll - 4609 (Hex)0x84351201 (Service Event)
Log Severity: Warning (2)
Log Message: Could not read from the registry sub-key. This error can be caused by a corrupt registry or a
low memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 4610 (Hex)0x84351202 (Service Event)
Log Severity: Warning (2)
Log Message: Could not write the registry sub-key: “%1”. This error can be caused by a corrupt registry or a
low memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 4611 (Hex)0x84351203 (Service Event)
Log Severity: Warning (2)
Log Message: Could not read the registry sub-key: “%1”. This error can be caused by a corrupt registry or a
low memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 4612 (Hex)0x84351204 (Service Event)
Log Severity: Warning (2)
Log Message: Could not read from the registry sub-key: “%1”. This error can be caused by a corrupt registry
or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 4613 (Hex)0x84351205 (Service Event)
Log Severity: Warning (2)
Log Message: Could not read from the registry sub-key: “%1”. This error can be caused by a corrupt registry
or a low memory condition. Rebooting the server may correct this error.
Event identifier: cpqhsmsg.dll - 4623 (Hex)0x8435120f (Service Event)
HPE Insight Management Agents for Servers for Windows 337