Cause
An issue exists with the system board.
CAUTION:
Only authorized technicians trained by Hewlett Packard Enterprise should attempt to remove the system
board. If you believe the system board requires replacement, contact Hewlett Packard Enterprise
technical support before proceeding.
Action
Contact Hewlett Packard Enterprise technical support.
For more information, see "Accessing Hewlett Packard Enterprise support."
162-System options error
Symptom
162-System options not set.
Cause
The configuration is incorrect.
The system configuration has changed after the last boot (for example, the addition of a hard drive).
A loss of power to the real-time clock has occurred (the real-time clock loses power if the onboard battery
is not functioning correctly).
Action
1. Press the F1 key to enter UEFI System Utilities.
2. Run the server setup utility to change the configuration.
For more information, see "UEFI System Utilities" in the HPE ProLiant Gen9 Troubleshooting Guide,
Volume I on the Hewlett Packard Enterprise website.
3. If the issue persists, replace the onboard battery.
For more information, see the maintenance and service guide on the Hewlett Packard Enterprise
website.
163-Time and date not set
Symptom
163-Time and date not set.
Cause
The time or date in the configuration memory is invalid.
Action
Run the server setup utility and correct the time or date.