Log Severity: Warning (2)
Event Title: SAS Tape Drive Status Change.
Log Message: The tape drive in %4, %5 with serial number "%6", has a new status of %7. (Tape Drive status
values: 1=other, 2=ok, 3=offline)
SNMP Trap: cpqSas2TapeDrvStatusChange - 5025 in CPQSCSI.MIB
Symptom: The Storage Agent has detected a change in the status of a SAS tape drive. The current tape drive
status is indicated in the cpqSasTapeDrvStatus variable.
Supporting SNMP Trap Data
• sysName
• cpqHoTrapFlags
• cpqSasHbaHwLocation
• cpqSasTapeDrvLocationString
• cpqSasTapeDrvHbaIndex
• cpqSasTapeDrvIndex
• cpqSasTapeDrvName
• cpqSasTapeDrvFWRev
• cpqSasTapeDrvSerialNumber
• cpqSasTapeDrvSasAddress
• cpqSasTapeDrvStatus
Supporting SNMP Trap Description: "Status is now %d."
NT Event ID: 1224 (Hex)0x843504c8 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Partner Controller Status Change.
Log Message: The Drive Array Controller in %4 has a Drive Array Partner Controller with serial number %5.
This Partner Controller has a new status of %2. (Partner Controller status values: 1=other, 2=ok,
3=generalFailure)
SNMP Trap: cpqDaCntlrPartnerStatusChange - 3048 in CPQIDA.MIB
Symptom: The agent has detected a change in the status of a drive array partner controller. The variable
cpqDaCntlrPartnerBoardStatus indicates the current partner controller status. The variable
cpqDaCntlrSerialNumber indicates the controller’s serial number and cpqDaCntlrPartnerSerialNumber
indicates the partner controller’s serial number.
User Action: Check the partner controller for problems. If lost communication with the partner controller is the
result of a user initiated action, no remedial action is required.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqDaCntlrHwLocation
• cpqDaCntlrIndex
388 HPE Insight Management Agents for Servers for Windows