sysName
cpqHoTrapFlags
cpqHeFltTolFanChassis
Supporting SNMP Trap Description: “The Fans are now redundant on Chassis [cpqHeFltTolFanChassis].”
NT Event ID: 1035 (Hex) 0x8435040BL (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: Corrected/uncorrected memory errors detected. The errors have been corrected, but the
memory module should be replaced. Value 0 for CPU means memory is not Processor based.
SNMP Trap: cpqHe5CorrMemReplaceMemModule - 6064 in CPQHLTH.MIB
Symptom: Corrected Memory Errors Detected. The errors have been corrected, but the memory module
should be replaced. Value 0 for CPU means memory is not processor-based.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqHeResMem2BoardNum
cpqHeResMem2CpuNum
cpqHeResMem2RiserNum
cpqHeResMem2ModuleNum
cpqHeResMem2ModulePartNo
cpqHeResMem2ModuleSize
cpqSiServerSystemId
Supporting SNMP Trap Description: “Correctable memory errors require a replacement of the memory
module in slot [cpqHeResMem2BoardNum], socket [cpqHeResMem2ModuleNum], Cpu
[cpqHeResMem2CpuNum] Riser [cpqHeResMem2RiserNum].” Correctable/uncorrectable memory errors
require a replacement of the memory module in slot [cpqHeResMem2BoardNum]], cpu
[cpqHeResMem2CpuNum], riser [cpqHeResMem2RiserNum], socket [cpqHeResMem2ModuleNum].
NT Event ID: 1036 (Hex) 0x4435040CL (cpqsvmsg.dll)
Log Severity: Informational (1)
Log Message: A memory board or cartridge has been removed from the system. Please reinsert the memory
board or cartridge.
SNMP Trap: cpqHe5ResMemBoardRemoved - 6065 in CPQHLTH.MIB
Symptom: Memory board or cartridge or riser removed. An Advanced Memory Protection sub-system board
or cartridge or riser has been removed from the system. Value 0 for CPU means memory is not processor-
based.
User Action: Be sure that the board, cartridge, or riser memory is installed correctly, and then re-install the
memory board, cartridge, or processor.
Supporting SNMP Trap Data: