EasyManua.ls Logo

HPE ProLiant Gen9

HPE ProLiant Gen9
460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Supporting SNMP Trap Description: “Connectivity is restored for adapter in slot [cpqNicIfPhysAdapterSlot],
port [cpqNicIfPhysAdapterPort].”
NT Event ID: 1291 (Hex)0xc435050B (cpqnimsg.dll)
Log Severity: Error (3)
Log Message: Connectivity has been lost for the NIC in slot %1, port %2.
SNMP Trap: cpqNic3ConnectivityLost - 18012 in CPQNIC.MIB
Symptom: This trap is sent any time the status of a logical adapter changes to the Failed condition. This
occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant
configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the
Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition.
User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the
adapter, Hub, or Switch may need replacement.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqNicIfPhysAdapterSlot
cpqNicIfPhysAdapterPort
cpqSiServerSystemId
cpqNicIfPhysAdapterStatus
cpqSePciSlotBoardName
cpqNicIfPhysAdapterPartNumber
ipAdEntAddr
cpqNicIfLogMapIPV6Address
Supporting SNMP Trap Description: “Connectivity lost for adapter in slot [cpqNicIfPhysAdapterSlot], port
[cpqNicIfPhysAdapterPort].”
NT Event ID: 1292 (Hex)0x4435050C (cpqnimsg.dll)
Log Severity: Information (1)
Log Message: Redundancy has been increased by the NIC in slot %1, port %2. Number of functional NICs in
the team: %3.
SNMP Trap: cpqNic3RedundancyIncreased - 18013 in CPQNIC.MIB
Symptom: This trap is sent any time a previously failed physical adapter in a connected logical adapter group
returns to the OK condition. This trap is not sent when a logical adapter group has connectivity restored from
a Failed condition. The cpqNicConnectivityRestored trap is sent instead. This can be caused by replacing of a
faulty cable or connecting a cable that was disconnected.
User Action: None required.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqNicIfPhysAdapterSlot
HPE Insight Management Agents for Servers for Windows 453