interface GigabitEthernet3/0/1
port hybrid pvid vlan 40
port hybrid untagged vlan 40
#
interface LoopBack1
ip address 2.2.2.9 255.255.255.255
#
bgp 100
peer 1.1.1.9 as-number 100
peer 1.1.1.9 connect-interface LoopBack1
peer 3.3.3.9 as-number 100
peer 3.3.3.9 connect-interface LoopBack1
#
ipv4-family unicast
undo synchronization
peer 1.1.1.9 enable
peer 3.3.3.9 enable
#
ipv6-family vpnv6
policy vpn-target
peer 1.1.1.9 enable
peer 3.3.3.9 enable
#
ipv6-family vpn6-instance vpn_in
peer 2003::1 as-number 65430
import-route direct
#
ipv6-family vpn6-instance vpn_out
peer 2004::1 as-number 65430
peer 2004::1 allow-as-loop
import-route direct
#
ospf 1
area 0.0.0.0
network 2.2.2.9 0.0.0.0
network 10.1.1.0 0.0.0.255
network 11.1.1.0 0.0.0.255
#
return
4.11.3 Example for Configuring Hub&Spoke (Using the Default
Route Between Hub-PE and Hub-CE)
Networking Requirements
As shown in Figure 4-4, the communication between Spoke-CEs is controlled by the Hub-CE
in the central site. That is, the traffic between Spoke-CEs is forwarded by the Hub-CE, and not
only by the Hub-PE. You need to configure the default route between the Hub-PE and the Hub-
CE.
Quidway S7700 Smart Routing Switch
Configuration Guide - VPN 4 BGP MPLS IPv6 VPN Configuration
Issue 01 (2011-07-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
395

Table of Contents

Other manuals for Huawei quidway s7700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei quidway s7700 and is the answer not in the manual?

Huawei quidway s7700 Specifications

General IconGeneral
Hot Swappable FansYes
IPv4 RoutingYes
IPv6 RoutingYes
MPLSYes
VLAN SupportYes
QoS SupportYes
Operating Temperature0°C to 45°C
Operating Humidity5% to 95% (non-condensing)
Product TypeSwitch
ManagementCLI, SNMP
Storage Temperature-40°C to 70°C
Power ConsumptionVaries by configuration
Slot Quantity3 (S7703); 6 (S7706); 12 (S7712)

Related product manuals