return
l Configuration file of CE2
#
sysname CE2
#
vlan batch 20
#
interface Vlanif 20
ip address 100.1.1.2 255.255.255.0
#
interface GigabitEthernet1/0/0
port link-type trunk
port trunk allow-pass vlan 20
#
return
5.11.2 Example for Configuring a Remote CCC Connection
Networking Requirements
The CE is connected to the PE through a GE interface.
To create a remote CCC connection between CE1 and CE2, you need to complete the following
tasks:
l Create the remote CCC connection between the two PEs.
l Configure two static LSPs on P to exchange packets.
Figure 5-5 Networking diagram for configuring remote CCC connection
Loopback1
2.2.2.9/32
CCC remote
connection
GE 2/0/0
GE 2/0/0 GE1/0/0
GE 1/0/0
GE 1/0/0 GE 2/0/0
GE 1/0/0 GE 1/0/0
P
PE2
PE1
CE 1 CE 2
O-Label
200
I-Label
200
O-Label
201
I-Label
201
I-Label
100
O-Label
100
I-Label
101
O-Label
101
CE 1 to CE 2
CE 2 to CE 1
Loopback1
1.1.1.9/32
Loopback1
3.3.3.9/32
Device
Interface VLANIF interface IP address
PE1 GigabitEthernet1/0/0 VLANIF 10 -
GigabitEthernet2/0/0 VLANIF 20 10.1.1.1/24
Quidway S7700 Smart Routing Switch
Configuration Guide - VPN 5 VLL Configuration
Issue 01 (2011-07-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
493