14-7
D Command table (continued)
14
CONTROL COMMAND
Cmd. Sub Cmd. Data Description
1A 05 0113 00 to 02 Send/read scope sweep speed for ±100
kHz span (00=Slow, 01=Mid., 02=Fast)
0114 00 to 02 Send/read scope sweep speed for ±250
kHz span (00=Slow, 01=Mid., 02=Fast)
0115
see p. 14-11
Send/read scope edge frequencies
for 0.03 to 1.60 MHz band
0116
see p. 14-11
Send/read scope edge frequencies
for 1.60 to 2.00 MHz band
0117
see p. 14-11
Send/read scope edge frequencies
for 2.00 to 6.00 MHz band
0118
see p. 14-11
Send/read scope edge frequencies
for 6.00 to 8.00 MHz band
0119
see p. 14-11
Send/read scope edge frequencies
for 8.00 to 11.00 MHz band
0120
see p. 14-11
Send/read scope edge frequencies
for 11.00 to 15.00 MHz band
0121
see p. 14-11
Send/read scope edge frequencies
for 15.00 to 20.00 MHz band
0122
see p. 14-11
Send/read scope edge frequencies
for 20.00 to 22.00 MHz band
0123
see p. 14-11
Send/read scope edge frequencies
for 22.00 to 26.00 MHz band
0124
see p. 14-11
Send/read scope edge frequencies
for 26.00 to 30.00 MHz band
0125
see p. 14-11
Send/read scope edge frequencies
for 30.00 to 45.00 MHz band
0126
see p. 14-11
Send/read scope edge frequencies
for 45.00 to 60.00 MHz band
0127 00/01 Send/read auto voice monitor set
(00=OFF, 01=ON)
0128 03 to 10 Send/read voice memory short
play time (03=3 sec. to 10=10 sec.)
0129 05 to 15 Send/read voice memory normal
record time (05= 5 sec. to 30=30 sec.)
0130 00 Normal selection for contest number
style
01 190ANO” selection for contest
number style
02 190ANT” selection for contest
number style
03 90NO” selection for contest number
style
04 90NT” selection for contest number
style
0131 01 to 04 Send/read count up trigger channel
(01=M1, 02=M2, 03=M3, 04=M4)
0132 0001 to
9999
Send/read present number
(0001=1, 9999=9999)
0133 01 to 60 Send/read CW keyer repeat time
(01=1 sec. to 60=60 sec.)
0134 28 to 45 Send/read CW keyer dot/dash ratio
(28=1:1:2.8 to 45=1:1:4.5)
0135 00 to 03 Send/read rise time
(00=2 msec., 01=4 msec.,
02=6 msec., 03=8 msec.)
0136 00/01 Send/read paddle polarity
(00=Normal, 01=Reverse)
0137 00 to 02 Send/read keyer type (00=Straight,
01=Bug-key, 02=ELEC-Key)
0138 00/01 Send/read mic. up/down keyer set
(00=OFF, 01=ON)
0139 00 to 03 Send/read FFT scope averaging set for
RTTY decoder
(00=OFF, 01=2, 02=3, 03=4)
0140
see p. 14-11
Send/read FFT scope waveform
color set for RTTY decoder
0141 00/01 Send/read RTTY decode USOS
(00=OFF, 01=ON)
Cmd. Sub Cmd. Data Description
1A 05 0142 00/01 Send/read RTTY decode new line code
(00=CR,LF,CR+LF, 01=CR+LF)
0143 00 to 02 Send/read RTTY diddle (00=OFF,
01=Blank, 02=LTRS (Letter code))
0144 00/01 Send/read RTTY TX USOS
(00=OFF, 01=ON)
0145 00/01 Send/read RTTY auto CR+LF by TX
(00=OFF, 01=ON)
0146 00/01 Send/read RTTY time stamp set
(00=OFF, 01=ON)
0147 00/01 Send/read clock selection for time
stamp(0=Local time, 1=CLOCK2)
0148 00/01 Send/read frequency stamp
(00=OFF, 01=ON)
0149
see p. 14-11
Send/readreceivedtextfontcolor
0150
see p. 14-11
Send/readtransmittedtextfontcolor
0151
see p. 14-11
Send/readtimestamptextfontcolor
0152
see p. 14-11
Send/readtextfontcolorinTXbuffer
0153 Send/read FFT scope averaging set for
PSK decoder
(00=OFF, 01=2, 02=3, 03=4)
0154
see p. 14-11
Send/read FFT scope waveform
color set for PSK decoder
0155 00/01 Send/read PSK AFC function tuning
range (00=±8 Hz, 01=±15 Hz)
0156 00/01 Send/read PSK time stamp set
(00=OFF, 01=ON)
0157 00/01 Send/read clock selection for time
stamp (00=Local time, 01=CLOCK2)
0158 00/01 Send/read frequency stamp
(00=OFF, 01=ON)
0159
see p. 14-11
Send/readreceivedtextfontcolorfor
PSK decoder
0160
see p. 14-11
Send/readtransmittedtextfontcolor
(PSK)
0161
see p. 14-11
Send/readtimestamptextfontcolor
(PSK)
0162
see p. 14-11
Send/readtextfontcolorinTXbuffer
(PSK)
0163 00/01 Send/read scan speed
(00=Low, 01=High)
0164 00/01 Send/read scan resume
(00=OFF, 01=ON)
0165
see p. 14-12
Send/read antenna selection for
0.03 to 1.60 MHz band
0166
see p. 14-12
Send/read antenna selection for
1.60 to 2.00 MHz band
0167
see p. 14-12
Send/read antenna selection for
2.00 to 6.00 MHz band
0168
see p. 14-12
Send/read antenna selection for
6.00 to 8.00 MHz band
0169
see p. 14-12
Send/read antenna selection for
8.00 to 11.00 MHz band
0170
see p. 14-12
Send/read antenna selection for
11.00 to 15.00 MHz band
0171
see p. 14-12
Send/read antenna selection for
15.00 to 20.00 MHz band
0172
see p. 14-12
Send/read antenna selection for
20.00 to 22.00 MHz band
0173
see p. 14-12
Send/read antenna selection for
22.00 to 26.00 MHz band
0174
see p. 14-12
Send/read antenna selection for
26.00 to 30.00 MHz band
0175
see p. 14-12
Send/read antenna selection for
30.00 to 45.00 MHz band
0176
see p. 14-12
Send/read antenna selection for
45.00 to 60.00 MHz band