HD2 Series Inverter Basic Operation Guidelines
-105-
Disconnection detected in
tension control
Disconnection is detected when the disconnection
detection is enabled in tension control.
Roll diameter setting
reached
The set roll diameter is reached during running in tension
control.
Max. roll diameter reached
The max. roll diameter is reached during running in
tension control.
Min. roll diameter reached
The min. roll diameter is reached during running in
tension control.
Fire control mode enabled
The fire mode is turned on.
0: Open collector high-speed pulse output
1: Open collector output
0: Invalid
1: In running
2: In forward running
3: In reverse running
4: In jogging
5: Inverter fault
6: Frequency level detection FDT1
7: Frequency level detection FDT2
8: Frequency reached
9: Running in zero speed
10: Reach upper limit frequency
11: Reach lower limit frequency
12: Ready to run
13: In pre-exciting
14: Overload pre-alarm
15: Underload pre-alarm
16: Simple PLC stage completed
17: Simple PLC cycle completed
18: Reach set counting value
19: Reach designated counting value
20: External fault is valid
21: Reserved
Relay RO1 output
selection
Relay RO2 output
selection