EasyManua.ls Logo

IMO HD2-3.7A-43 - Page 155

IMO HD2-3.7A-43
408 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HD2 Series Inverter Function Parameter List
-146-
Function
code
Name
Description
Default
value
Modify
motor 1
P02.08
Leakage
inductance of
asynchronous
motor 1
0.1–6553.5mH
Depends
on model
P02.09
Mutual
inductance of
asynchronous
motor 1
0.1–6553.5mH
Depends
on model
P02.10
No-load current
of asynchronous
motor 1
0.1–6553.5A
Depends
on model
P02.11
Magnetic
saturation
coefficient 1 of
iron core of
asynchronous
motor 1
0.0–100.0%
80.0%
P02.12
Magnetic
saturation
coefficient 2 of
iron core of
asynchronous
motor 1
0.0–100.0%
68.0%
P02.13
Magnetic
saturation
coefficient 3 of
iron core of
asynchronous
motor 1
0.0–100.0%
57.0%
P02.14
Magnetic
saturation
coefficient 4 of
iron core of
asynchronous
motor 1
0.0–100.0%
40.0%
P02.15
Rated power of
synchronous
0.1–3000.0kW
Depends
on model

Table of Contents

Related product manuals