HD2 Series Inverter Function Parameter List
-146-
Function
code
Name
Description
Default
value
Modify
motor 1
P02.08
Leakage
inductance of
asynchronous
motor 1
0.1–6553.5mH
Depends
on model
○
P02.09
Mutual
inductance of
asynchronous
motor 1
0.1–6553.5mH
Depends
on model
○
P02.10
No-load current
of asynchronous
motor 1
0.1–6553.5A
Depends
on model
○
P02.11
Magnetic
saturation
coefficient 1 of
iron core of
asynchronous
motor 1
0.0–100.0%
80.0%
○
P02.12
Magnetic
saturation
coefficient 2 of
iron core of
asynchronous
motor 1
0.0–100.0%
68.0%
○
P02.13
Magnetic
saturation
coefficient 3 of
iron core of
asynchronous
motor 1
0.0–100.0%
57.0%
○
P02.14
Magnetic
saturation
coefficient 4 of
iron core of
asynchronous
motor 1
0.0–100.0%
40.0%
○
P02.15
Rated power of
synchronous
0.1–3000.0kW
Depends
on model
◎

Table of Contents