HD2 Series Inverter Function Parameter List
-147-
Function
code
Name
Description
Default
value
Modify
motor 1
P02.16
Rated frequency
of synchronous
motor 1
0.01Hz–P00.03 (Max. output frequency)
50.00Hz
P02.17
Number of pole
pairs of
synchronous
motor 1
1–128
2
P02.18
Rated voltage of
synchronous
motor 1
0–1200V
Depends
on model
P02.19
Rated current of
synchronous
motor 1
0.8–6000.0A
Depends
on model
P02.20
Stator resistance
of synchronous
motor 1
0.001–65.53
Depends
on model
P02.21
Direct-axis
inductance of
synchronous
motor 1
0.01–655.35mH
Depends
on model
P02.22
Quadrature-axis
inductance of
synchronous
motor 1
0.01–655.35mH
Depends
on model
P02.23
Counter-emf
constant of
synchronous
motor 1
0–10000
300
P02.24
Reserved
0x0000–0xFFFF
0
P02.25
Reserved
0%50% (of the motor rated current)
10%
P02.26
Overload
protection of
motor 1
0: No protection
1: Common motor (with low-speed compensation).
As the cooling effect of common motor will be
degraded in low speed, the corresponding
electronic thermal protection value should also be
adjusted properly, the low compensation here
means to lower the overload protection threshold
2