HD2 Series Inverter Function Parameter List
-163-
Enable/disable IF
mode for
asynchronous
motor 2
Current setting in
IF mode for
asynchronous
motor 2
When IF control is adopted for asynchronous
motor 2, this parameter is used to set the output
current. The value is a percentage in relative to the
rated current of the motor.
Setting range: 0.0–200.0%
Proportional
coefficient in IF
mode for
asynchronous
motor 2
When IF control is adopted for asynchronous
motor 2, this parameter is used to set the
proportional coefficient of the output current
closed-loop control.
Setting range: 0–5000
Integral
coefficient in IF
mode for
asynchronous
motor 2
When IF control is adopted for asynchronous
motor 2, this parameter is used to set the integral
coefficient of the output current closed-loop
control.
Setting range: 0–5000
Starting
frequency point
for switching off
IF mode for
asynchronous
motor 2
End frequency
point for
switching off IF
mode for
asynchronous
motor 1
End frequency
point for
switching off IF
mode for
asynchronous
motor 2