HD2 Series Inverter Function Parameter List
-277-
Function
code
Name
Description
Default
Modify
P93.11
Actual integral
time
0.00–30.00s
0.00
P93.12
Proportional
output value
0–65535
0
P93.13
Integral output
value
0–65535
0
P93.14
PID upper limit
-100.0–100.0%
0.0
P93.15
PID lower limit
-100.0–100.0%
0.0
P93.16
PID output
frequency
-99.99–99.99Hz
0.00
P93.17
Main traction
running
frequency
-300.0–300.0Hz
0.0
P93.18
Set tension
0–30000N
0
P93.19
Tension taper
coefficient
0.0–100.0%
0.0
P93.20
Actual tension
0–30000N
0
P93.21
Basic torque
reference value
-300.0–300.0%
0.0
P93.22
Friction
compensation
torque value
-300.0–300.0%
0.0
P93.23
System rotational
inertia
0.00–655.35 kg.m
2
0.00
P93.24
Frequency
change rate
-99.99–327.67 Hz/s
0.00
P93.25
Torque
compensation
value of system
rotational inertia
-300.0–300.0%
0.0
P93.26
Reference value
after torque
compensation
-300.0–300.0%
0.0
P93.27
PID output torque
-300.0–300.0%
0.0
P93.28
Final output
torque
-300.0–300.0%
0.0
P93.29
Measured
tension
0–30000N
0