HD2 Series Inverter Function Parameter List
-276-
Function
code
Name
Description
Default
Modify
1: Report an alarm and coast to stop
Hundreds place: Roll diameter memory function of
feeding interrupt
0: Disable
1: Enable
P92.14
Stop braking
frequency
0.00–300.00Hz
1.50
P92.15
Stop braking time
0.0–600.0s
0.0
P93––Tension control status viewing
Function
code
Name
Description
Default
Modify
P93.00
Actual control
mode
03
0: Invalid tension control
1: Close-loop tension speed control
2: Open loop tension torque control
3: Close-loop tension torque control
0
P93.01
Actual winding/
unwinding mode
01
0: Winding
1: Unwinding
0
P93.02
Initial roll
diameter
0.0–5000.0mm
0.0
P93.03
Reset roll
diameter
0.0–5000.0mm
0.0
P93.04
Roll diameter
change rate
0.00–655.35 mm/s
0.00
P93.05
Present roll
diameter
0.0–5000.0mm
0.0
P93.06
Roll diameter for
linear speed
calculation
0.0–5000.0mm
0.0
P93.07
Set linear speed
0.0–6000.0 m/min
0.0
P93.08
Present linear
speed
0.0–6000.0 m/min
0.0
P93.09
Main reference
frequency
0.00–600.00Hz
0.00
P93.10
Actual
proportional gain
0.00–30.00
0.00