HD2 Series Inverter Function Parameter List
-275-
Function
code
Name
Description
Default
Modify
limit setting
P92.03
Zero-bit
conversion
enabling
01
0: Disable
1: Enable
0
P92.04
Initial zero bit
0.0–100.0%
10.0
P92.05
Final zero bit
0.0–100.0%
50.0
P92.06
Conversion time
from initial zero
bit to final zero bit
0.00–60.00s
5.00
P92.07
Conversion time
from final zero bit
to initial zero bit
0.00–60.00s
5.00
P92.08
Feeding interrupt
detection mode
03
0: Not detect
1: Detect based on digital value
2: Detect based on roll diameter calculation value
3: Detect based on feedback position
0
P92.09
Feeding interrupt
detection start
delay time
0.0–200.0s
20.0
P92.10
Frequency lower
limit of feeding
interrupt
detection
0.00–300.00Hz
10.00
P92.11
Error range of
feeding interrupt
detection
0.1–50.0%
10.0
P92.12
Determination
delay time of
feeding interrupt
detection
0.1–60.0s
1.0
P92.13
Handling mode of
feeding interrupt
0x0000x111
Ones place: Stop mode
0: Decelerate to stop in emergency manner
1: Coast to stop
Tens place: Alarm mode
0: Stop in enabled stop mode without reporting an
alarm
0x000

Table of Contents