An error is returned in the following conditions. The instruction is not executed. The error ag M8067 is set
to ON to identify this error and the error code is stored in D8067.
1. Error 6705 is returned when elements from head addresses [S1] and [S2] are out of range.
2. Error 6705 is returned when [S1] and [S2] have overlapping elements with [D].
Application
MAND: Matrix AND operation
Overview
The MAND instruction performs AND operation in matrix format.
MAND S1 S2 D n
Matrix AND
operation
Applicable model:
H3U
S1 Matrix 1 Operand element 1 in an operation
16-bit instruction (9
steps)
MAND: Continuous
execution
MANDP: Pulse
execution
S2 Matrix 2 Operand element 2 in an operation
D
Operation
result
Start number of elements that store the operation
result
n Data count
Number of data entries in an operation; value range:
1 to 256