EasyManua.ls Logo

Inovance H3U Series - Appendix B System Error Code

Inovance H3U Series
737 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B.1 System Error Code D8060
720
Appendix
Appendix B System Error Code
The following table lists error codes.
B.1 System Error Code D8060
Error Code Error
D8060 I/O range or setting error
1000-1377 X input signal error: incorrect or limit-exceeding serial number
0000-0377 Y input signal error: incorrect or limit-exceeding serial number
B.2 System Error Code D8061
Error Code Content
D8061 PC hardware error denition
6101 RAM error
6102 Operation circuit error
6103 I/O hardware connection error
6104 External 24V power supply error
6105 System monitor error
6106 System ash read/write error
6107 System I/O setting error
6108 FPGA download error
6109 FPGA conguration data error in ash
6110 Ethernet hardware initialization failure
6111 Extension module conguration different from the actual
6112-6199 Reserved
16100-16199 Reserved
26100-26199 Reserved
B.3 System Error Code D8062
Error Code Content
D8062 Communication error in control panel or program connection port
6200-6279 serial communication and conguration error codes
6201 Odd/even check error, overow error, and frame error
6202 Incorrect communication character
6203 Inconsistent communication data sum
6204 Incorrect data format
6205 Incorrect instruction
6206 Communication element exceeding range
6207 Communication port exceeding range or not existing
6208-6279 Reserved
6280-6299 CAN communication conguration error code
16200-16219 Ethernet conguration error code
16200 Reserved
16201 Ethernet conguration: unsupported parameter number
16202
Ethernet conguration: incorrect head register address or incorrect head
address plus number of registers

Table of Contents

Other manuals for Inovance H3U Series

Related product manuals