EasyManua.ls Logo

Inovance H3U Series - Troubleshooting for Canlink Communication

Inovance H3U Series
737 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
634
9
9 Communication9.6.5 Troubleshooting for CANlink Communication
AC drivecontrolinstruction
WriteACdrive control enabling
9.6.5 Troubleshooting for CANlink Communication
Indicator State Indication
Communication
(green)
Off CANlink bus not connected or disconnected
On
CANlink bus connected (remote frames received on
the node)
Blinking ( ≤ 3 Hz)
During CANlink communication, one blink per frame of
bus data sent or received
Blinking (5Hz) Flag monitor
Fault (red)
Off No fault
On Monitor timeout (node), no node (monitor)
Blinking (0.5Hz) CANlink conguration error (for the congurator)
Blinking (1Hz) Node lost or crash (for the monitor)
Blinking (5Hz) CANlink address conict