4 Instructions4.9.6 Refreshing
AXISALMRST: Axis alarm reset
Overview
The AXISALMRST instruction resets axis alarms based on CANlink.
AXISALMRST
S1
Axis alarm reset Applicable model:
H3U
S1
Axis
number
Servo station number, in the range 1 to 16
16-bit instruction (3
steps)
AXISALMRST:
Continuous execution
Operands
Operand
Bit Element Word Element
System·User System·User Bit Designation Indexed Address Constant
Real
Number
S1
X Y M T C S SM D R T C SD KnX KnY KnM KnS KnSM V Z Modication K H E
Function
The alarm of the servo corresponding to a designated station or axis number will be reset. Some servo
alarms cannot be reset by this instruction. Use this instruction to reset an alarm after the corresponding
fault is rectied. The axis number must be an immediate value.
Example
M1
Servo reset
alarm bit
When M1 = 1, alarm reset is enabled for servo 1. When M1 = 0, alarm reset is disabled for servo 1.
This instruction can be executed only once for every axis.
This instruction is supported by 24304 and later versions.
4.9.6 Refreshing
Refreshing
REF Input/Output refreshing