510
7
7 Motion Control
DRVZ: Mechanical zero return
X-axis Y-axis Z-axis Attribute
SM12 SM112 SM212 Flag of DRVZ zero return direction
6) Disabling zero return for a specic axis
The axis zero return disabling function of special elements can be used to disable the specied axis to
return to the origin, and allow other axes to return to the origin. See the following table.
X-axis Y-axis Z-axis Attribute
SM18 SM118 SM218 Axis origin return disabled
7) Logic signal inversion
See the following table.
OFF: Positive logic (when the input is ON, the near point/origin signal is ON).
ON: Negative logic (when the input is OFF, the near point/origin signal is ON).
X-axis Y-axis Z-axis Attribute
SD80 SD180 SD280 Selection of the input pole
SDX80: Selects the input pole
Bits of this element are dened in the following table.
b0
Enter the A signal polarity
0 indicates the positive polarity, which is valid when ON is entered. 1 indicates the negative
polarity, which is valid when OFF is entered.
b1
Enter the B signal polarity
0 indicates the positive polarity, which is valid when ON is entered. 1 indicates the negative
polarity, which is valid when OFF is entered.
b2
Enter the START signal polarity
0 indicates the positive polarity, which is valid when ON is entered. 1 indicates the negative
polarity, which is valid when OFF is entered.
b3
Enter the DOG signal polarity
0 indicates the positive polarity, which is valid when ON is entered. 1 indicates the negative
polarity, which is valid when OFF is entered.
b4
Enter the STOP signal polarity
0 indicates the positive polarity, which is valid when ON is entered. 1 indicates the negative
polarity, which is valid when OFF is entered.
b5
Enter the LSN signal polarity
0 indicates the positive polarity, which is valid when ON is entered. 1 indicates the negative
polarity, which is valid when OFF is entered.
b6
Enter the LSP signal polarity
0 indicates the positive polarity, which is valid when ON is entered. 1 indicates the negative
polarity, which is valid when OFF is entered.
b7
Enter the PG signal polarity
0 indicates the positive polarity, which is valid when ON is entered. 1 indicates the negative
polarity, which is valid when OFF is entered.
b15 to b8 Reserved