575
8
8 Electronic Cam 8.5.5 Flag of End of Cycle and Flag of End
When M77 is set to ON, the slave axis zoom ratio is set to 2 (SD173/100 = 2) and will take effect in the next
cam cycle.
When M76 is set to ON, the slave axis zoom ratio is set to 0.5 (SD173/100 = 0.5) and will take effect in the
next cam cycle.
8.7 Ejector Pin
The ejector pin can turn on and off bit elements (M and Y elements) based on the master axis position. The
following describes how to set the ejector pin.
1. On the cam curve editing page, click
Ejector Pin
.
2. Click the
Add
or
Del
icon to add or delete data respectively.
3. Congure the ejector pin in the table:
M-Pos: Sets the master axis position for an electronic cam.
Type: Sets the type of a bit element (M or Y).
Addr: Sets the element number.
Action: Indicates the action when the master axis position matches the M-Pos value. NA indicates no
action. ON indicates that the element is set to ON. OFF indicates that the element is set to OFF. INV
indicates inversion operation.
Axis: Indicates the axis property. When the property of a slave axis matches the Axis value, the ejector pin
data is valid. As shown in the following gure, you can select the axis property in the drop-down box.

Table of Contents

Other manuals for Inovance H3U Series